SETUP

SETUP

Lamp

You will need to install a lamp prior to the initial operation of the fixture. A HMI575 high intensity discharge lamp is included.

Warning!

When replacing the lamp, please wait 15 minutes after powering down to allow the

 

unit to cool down! Always disconnect from main power prior to lamp replacement.

Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with alcohol and wipe it with a lint free cloth before installation.

Lamp Installation

 

S1

1. Unscrew thumbscrews (S1) to

 

 

 

detach the top cover.

 

 

 

 

1

2. Unscrew screws (S2) to remove

1

 

 

 

lamp cover and expose lamp

S2

2

compartment.

 

 

 

 

3

3.

Move lamp reflector back as indicated by the arrow.

 

 

 

 

 

4.

If installing a new lamp, loosen both screws on the

 

 

 

 

 

 

double ended lamp to allow for the lamp to slide into the

 

 

 

 

 

 

lamp socket slots. Lower lamp evenly.

 

 

 

 

 

5.

If replacing a lamp, loosen both lamp screws

 

 

 

 

 

 

 

(S3) to relieve tension from lamp socket slots

 

S3

5

 

 

so you can slide the lamp freely, upwards and

 

 

 

out of lamp socket. Raise lamp evenly to

 

 

 

 

 

 

 

remove.

 

 

 

 

 

 

6.

Before you tighten the lamp end screws,

 

 

 

 

 

 

 

rotate the bulb until the nipple on the envelope

 

 

 

 

 

 

 

(N) of the bulb is facing upwards as illustrated.

 

 

 

 

 

 

7.

If you are replacing the lamp, you may want to

 

 

 

 

 

 

 

 

 

 

6

 

log the fixture hours in order to track the lamps

 

 

 

 

 

 

 

 

 

 

use. Navigate to the {LPti} on the menu display to obtain this

 

information. (Page 9, Control Board Functions)

 

 

 