![General Troubleshooting](/images/new-backgrounds/43047/4304715x1.webp)
General Troubleshooting
Symptom
Solution(s)
Applies to
Lights | Foggers | Controllers | Dimmers |
& Snow | & Chaser | ||
|
|
|
|
| Auto shut off | Check fan thermal switch reset | 9 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Beam is very dim or | Clean optical system or replace lamp | 9 |
|
|
|
| not bright | Check 220/110v switch for proper setting |
|
|
|
|
| Breaker/Fuse keeps | Check total load placed on device |
|
|
| 9 |
| blowing |
|
|
|
|
|
| Chase is too slow | Check users manual for speed adjustment | 9 |
| 9 | 9 |
|
|
|
|
|
|
|
| Device has no power | Check for power on Mains. | 9 |
| 9 | 9 |
|
| Check device’s fuse. (internal and/or external) |
|
|
|
|
| Fixture is on but | Make sure you have the correct audio mode on the |
|
|
|
|
| there is no | control switches. If audio provided via ¼” jack, make | 9 |
| 9 | 9 |
| movement to the | sure a live audio signal exists |
|
|
|
|
| audio | Adjust sound sensitivity knob |
|
|
|
|
| Lamps cuts off | Possible bad lamp or fixture is overheating. | 9 |
|
|
|
| sporadically | Lamp may be at end of its life. |
|
|
|
|
| Light will not come | Some discharge lamps require a cooling off period | 9 |
|
|
|
| on after power failure | before the electronics in the fixture can kick start it |
|
|
| |
|
| again, wait 5 to 10 minutes before powering up |
|
|
|
|
| Moves slow | Check 220/110v switch for proper setting | 9 |
|
|
|
|
|
|
|
|
|
|
| No flash | 9 |
|
|
| |
|
|
|
|
|
|
|
| No light output | Check slip ring & brushes for contact | 9 |
|
|
|
|
| Install bulb |
|
|
| |
|
| Call service technician |
|
|
|
|
| Relay will not work | Check reset switch |
|
|
| 9 |
|
| Check cable connections |
|
|
|
|
| Remote does not | Make sure connector is firmly connected to device | 9 | 9 |
|
|
| work |
|
|
|
|
|
| Stand alone mode | All Chauvet lighting fixtures featuring |
|
|
|
|
|
| functions do not require additional settings, simply | 9 |
|
|
|
|
| power the fixture and it will automatically enter into this |
|
|
| |
|
| mode |
|
|
|
|
|
|
|
|
|
|
|
*Note not all values apply to all fixtures
If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location below.
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954)
Fax: (954)
Website: http://www.chauvetlighting.com
LX5 | 8 | 9/17/2007 12:27 PM |