General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

 

 

 

Blown Fuse/

Short circuit along the power wires

Replace Fuse

Tripped Breaker

Excessive circuit load

Reset Breaker

 

 

 

 

No power

Check for power on power outlet

Device does not

Loose power cord

Check power cord

 

 

power up

Blown Fuse

Replace Fuse

 

 

Reset Breaker

Reset Breaker

 

Wrong DMX addressing

Check Control Panel and unit

 

addressing

 

 

 

Damaged DMX cables

Check DMX cables

Fixture is not

Wrong polarity settings on the controller

Check polarity switch settings on the

responding to

controller

 

DMX

 

Loose DMX cables

Check cable connections

 

 

Faulty DMX interface

Replace DMX input

 

Faulty Main PCB

Replace Main PCB

 

 

 

 

Bouncing signals

Install terminator as suggested

Loss of signal

Long cable / Low level signal

Install amplifier right after fixture with

strong signal

 

 

 

 

Interference from AC wires

Keep DMX cables separated from

 

power cables or black lights

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET® Technical Support.

Contact Us

World W ide

General Information

CHAUVET®

 

3000 North 29th Court

 

Hollywood, FL 33020

 

voice:

954.929.1115

 

fax:

954.929.5560

 

toll free: 800.762.1084

Technical Support

CHAUVET®

 

3000 North 29th Court

 

Hollywood, FL 33020

 

voice:

954.929.1115 (Press 4)

 

fax:

954.929.5560 (Attention: Service)

World Wide Web

www.chauvetlighting.com

5. Appendix

12

5/7/2010 1:21 PM

Page 12
Image 12
Chauvet Work Light user manual General Troubleshooting, Contact Us