DVBR Series Direct Vent Gas Fireplace

Troubleshooting – Honeywell VS8421

 

 

 

Remove window frame assembly before service work

 

 

START

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

Gas Supply On

 

NO

 

 

Supply Line Hooked Up

 

 

 

 

 

 

 

 

 

 

Shutoff Valve Open

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lockout Has Engaged. Wait 60

 

 

 

 

 

 

 

 

 

Seconds And Try Again.

 

 

 

 

 

 

 

 

For Spark At Electrode While

 

 

 

Pilot Lights With Piezo

 

 

 

 

 

 

 

NO

 

 

 

Depressing Piezo

 

 

 

Ignitor

 

 

 

 

 

1/8" Gap To Pilot Hood Needed.

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Piezo Ignitor

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Air In The Lines

 

 

 

 

 

 

 

 

Thermopile Needs A Min.

 

 

 

 

 

 

 

 

 

325mv. Adjust Pilot Flame

 

 

 

 

 

 

 

 

 

Height.

 

 

 

 

 

 

 

 

All Wiring Connections

 

 

 

PILOT STAYS LIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Replace Thermopile

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermocouple Needs A Min. Of

 

 

 

 

 

 

 

 

 

14mv

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Is Turned On

 

 

 

 

 

 

 

 

Wall Switch Is Not Turned On.

 

 

 

PILOT LIGHTS MAIN

 

 

 

 

 

 

 

NO

 

 

 

Watch For Grounded Wires!

 

 

 

BURNER

 

 

 

Thermopile Needs A Min. 325mv.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plugged Burner Orifice

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

Defective Valve. Turn To Pilot,

 

 

 

 

 

 

 

 

 

Meter Should Read Greater Than

 

 

 

 

 

 

 

 

 

100mv. If Not, Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

20000584

Page 28
Image 28
Vermont Casting DVBR42, DVBR36 manual Troubleshooting Honeywell VS8421, Remove window frame assembly before service work