DVBR Series Direct Vent Gas Fireplace

DVBR42

1.Remove the seven (7) screws securing the heat shield cover plate to the fireplace. (Fig. a) Discard the heat shield cover plate.

Remove Screws (7)

Heat Shield

Cover Plate

FP1542

Fig. a Remove screws securing heat shield cover plate. Dis- card cover plate.

2.Carefully remove the square piece of insulation along the perforations. (Fig. b) Discard insulation.

3.Remove the eight (8) screws securing outer collar adapter to fireplace. (Be careful not to damage insu- lation.) (Fig. 10)

Remove Insulation

FP1543

Fig. b Remove and discard insulation.

4.Set outer collar adapter aside.

5.Remove insulation on top of collector box. (Fig. 11)

6.Remove the four (4) screws securing flue cover to top of unit and remove flue cover. (Fig. 11)

7.Remove the four (4) screws securing flue pipe to back of unit. Remove flue pipe. (Fig. 11)

8.Secure flue cover to back of flue outlet. Be sure to replace gasket. (Fig. 12)

9.Install flue pipe to top of unit with four (4) screws. Be sure to replace gasket. (Fig. 12)

10.Set insulation in back of unit foil side down.

11.Secure outer collar adapter to unit with the round collar on top, secure with eight (8) screws.

NOTE: Be sure not to damage any gasket material.

General Venting

Your fireplace is approved to be vented either through the side wall, or vertical through the roof.

Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace may be used.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope.

Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1/2” (13 mm) per12” (305 mm).

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on the following page.

10

20000584

Page 10
Image 10
Vermont Casting DVBR42, DVBR36 manual General Venting, Location of Vent Termination