Optional Top Vent Application

The DVBR36/42 fireplace is shipped as a rear vent unit. If the layout requires a top vent, convert the unit follow- ing the steps below.

DVBR36

1.Remove the eight (8) screws securing outer collar adapter to fireplace. (Be careful not to damage insu- lation.) (Fig. 10)

2.Set outer collar adapter aside.

Remove

Rear View

Screws (4)

 

Outer Collar

Adapter

Flue Pipe

Remove Screws (4)

DVT584-602

Fig. 10 Remove screws from outer collar adapter.

3.Remove insulation on top of collector box. (Fig. 11)

4.Remove the four (4) screws securing flue cover to top of unit and remove flue cover. (Fig. 11)

5.Remove the four (4) screws securing flue pipe to back of unit. Remove flue pipe. (Fig. 11)

 

 

Insulation

 

 

Remove

Flue

 

Screws (4)

 

 

Cover

 

 

Flue

 

 

Pipe

 

 

 

Remove Screws

DVT584-603

 

(4)

 

 

Fig. 11 Remove flue cover and flue pipe.

DVBR Series Direct Vent Gas Fireplace

6.Secure flue cover to back of flue outlet. Be sure to replace gasket. (Fig. 12)

7.Install flue pipe to top of unit with four (4) screws. Be sure to replace gasket. (Fig. 12)

8.Set insulation in back of unit foil side down.

9.Secure outer collar adapter to unit with the round collar on top, secure with eight (8) screws.

NOTE: Be sure not to damage any gasket material.

Flue Pipe

Flue

Pipe Replace

Screws (4)

Replace Screws

(4)

Foil Side

Insulation

DVT584-604

Fig. 12 Replace flue cover and flue pipe.

 

DVT584-605

Fig. 13

Completed conversion.

20000584

9

Page 9
Image 9