DVBR Series Direct Vent Gas Fireplace
20” (506 mm)
Max.
Top View Flat Installation
FP1188
Fig. 19 Rear vent application, no elbows.
20” (506 mm) Max.
Top View Corner Installation | FP1188 |
Fig. 20 Rear vent application, one 45° elbow.
Rear Wall Vent Installations -
Twist Lock Pipe
Step 1
Locate and cut the vent opening in the wall.
For combustible walls first frame in opening. (Fig. 21)
NOTE: When using flex vent, the opening will have to be measured according to the 1” (25 mm) rise in 24” (610 mm) vertical run.
Combustible Walls: Cut a 10³⁄₈”H x 9³⁄₈” W (265 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 21)
Noncombustible Walls: Hole opening should be 7¹⁄₂” (191 mm) diameter.
Zero clearance sleeve is only required for combustible walls.
Step 2
Measure wall thickness and cut zero clearance sleeve parts to proper length (Maximum 12” / 305mm). As- semble sleeve to its maximum opening (10³⁄₈” x 9³₈”) and attach to firestop assembly. (Fig. 22)
Step 3
Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 20)
Vent Opening - Combustible Wall
9³⁄₈"
(240 mm)
10³⁄₈" | Framing |
Detail |
(265 mm)
Fireplace Hearth
Vent Opening - Noncombustible Wall
7¹⁄₂" Dia.
(191 mm)
Fireplace Hearth |
Fig. 21 Locate vent opening on wall.
| Max. Length |
| 12” (294 mm) |
| #8 Screws (2) |
| Firestop |
#8 Screws (2) |
|
#8 Screws |
|
(2) |
|
Adjustable Zero |
|
Clearance Sleeve | CFM135a |
Fig. 22 Adjustable zero clearance sleeve.
Step 4
Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheet metal screws. Install the 7” (175 mm) vent pipe to the appliance collar and secure with three (3) sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used attach the elbow to the appliance in the same manner then at- tach the venting to the elbow.
It is critical that there is no downward slope away from the appliance when con- necting the vent or elbow.
Step 5
Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4”
(102 mm) and 7” (175 mm) collar of the vent termina- tion into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appli- ance flue collars. (Fig. 23) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.
14 | 20000584 |