F-4

 

 

 

 

 

 

 

 

F-4

TROUBLESHOOTING & REPAIR

 

 

 

Observe Safety Guidelines

 

 

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

Major physical or electrical damage

1. Contact your local Lincoln

1.

Contact the

Lincoln Electric

is evident.

Authorized

 

Field

Service

 

Service Department at 1-800-

 

Facility.

 

 

 

 

 

833-9353 (WELD)

 

 

 

 

 

 

 

No welding output in neither Stick

1. Place the Welding Terminals

1.

Check for loose or faulty con-

or CV modes. The engine operates

Switch in the "ALWAYS ON"

 

nections on the heavy current

normally. The auxiliary output is

position.

If

the problem is

 

carrying leads between the out-

normal.

solved, the fault may be in the

 

put bridge, the power modules,

 

external control cable (if used),

 

the choke and the output termi-

 

leads #2

and #4.

See the

 

nals.

 

 

 

 

Wiring Diagram.

 

2.

Check the Welding Terminals

 

 

 

 

 

 

 

2. With the engine at high idle

 

Switch and

associated

leads.

 

(1900RPM), the machine in the

 

See the Wiring Diagram.

 

 

 

Stick mode and the OUTPUT

3.

Check gate

leads #23,

#23A,

 

CONTROL at maximum, check

 

 

#25 and #25A for loose or faulty

 

for the

presence of

approxi-

 

 

 

connections.

See the

Wiring

 

mately 87VDC (open circuit volt-

 

 

 

Diagram.

 

 

 

 

age) at the output terminals.

 

 

 

 

 

 

 

 

 

 

 

3. If the correct OCV is present at

4.

Perform the

Stator Voltage

 

 

Test.

 

 

 

 

the welding

output

terminals

 

 

 

 

 

 

 

 

 

 

 

check

the

welding

cables,

5.

Perform the

Output Rectifier

 

clamps and electrode holder for

 

Bridge Test.

 

 

 

 

loose or faulty connections.

6.

Perform the

Power Module

 

 

 

 

 

 

 

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

7.

Perform the

Analog

Power

 

 

 

 

 

 

 

Supply PC Board Test.

 

 

 

 

 

 

 

 

8.

The Weld Control PC Board

 

 

 

 

 

 

 

may be faulty.

 

 

 

 

 

 

 

 

9.

See the Start-Up and OCV

 

 

 

 

 

 

 

Diagnostic Chart.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

COMMANDER 500

Page 57