TROUBLESHOOTING & REPAIR

OUTPUT RECTIFIER BRIDGE DIODE REMOVAL AND REPLACEMENT

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

DESCRIPTION

The following procedure will aid the technician in removing and replacing stud type diodes to the aluminum heat sinks on the Commander 500.

MATERIALS NEEDED

7/16" Wrench

1/2” Wrench

1" Open end wrench

Penetrox A13 joint compound (T12837-1) -2 gm. tube Loctite 271

"Slip" type torque wrench

E2827-2 abrasive disc or fine steel wool

This procedure should take approximately 25 minutes to perform.

COMMANDER 500

Page 123
Image 123