F-11

 

 

F-11

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

 

The engine will not go to high idle

1. Make sure the auxiliary power

1.

Check the current sensing

 

when using the auxiliary power.

leads are tight.

 

toroid for loose or faulty connec-

 

Auxiliary power is normal when the

2. The automatic idler may not

 

tions. See the Wiring Diagram.

 

IDLER switch is in the "HIGH" posi-

 

 

 

 

function if the auxiliary power is

2.

Make sure leads #3 and #6A

 

tion. Automatic idle function works

 

loaded to less than 150 watts.

 

pass through the toroid twice in

 

properly when the welding termi-

 

 

 

 

opposite directions.

 

nals are loaded.

 

 

 

 

 

 

 

 

 

 

3.

The current sensing toroid may

 

 

 

 

be faulty.

 

 

 

4.

The Weld Control PC board

 

 

 

 

may be faulty.

 

 

 

 

 

 

 

The engine will not go to high idle

1. Make sure the welding cables

1.

The Weld Control PC board

 

when attempting to weld or when

and auxiliary power lead con-

 

may be faulty.

 

the auxiliary power is loaded.

nections are tight.

2.

The current sensing toroid may

 

Welding output and auxiliary power

 

 

 

 

be faulty.

 

outputs are normal when IDLER

 

 

 

 

 

 

 

 

switch is in the " HIGH" position.

 

 

 

 

 

 

 

 

 

 

 

The machine goes to low idle but

1. Make sure there is NOT an

1.

The idler solenoid linkage may

 

does not stay at low idle.

external load (auxiliary or weld)

 

be misadjusted or damaged.

 

 

connected to the Commander

2.

The idler solenoid lead connec-

 

 

500.

 

 

 

tions may be loose or damaged.

 

 

 

 

 

 

 

 

See the Wiring Diagram.

 

 

 

3.

Perform the Idler Solenoid

 

 

 

 

Test.

 

 

 

4.

The Weld Control PC board

 

 

 

 

may be faulty.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.