Lincoln Electric SVM153-A service manual Retest After Repair, Engine RPM, Welder DC Stick Output

Models: SVM153-A

1 156
Download 156 pages 27.22 Kb
Page 135
Image 135

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-82

F-82

 

 

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

ENGINE RPM

Mode

No Load RPM

Load RPM

 

 

 

Low Idle

1400 - 1450

NA

High Idle

1890 - 1910

1750 - 1890

 

 

 

 

 

 

WELDER DC (STICK) OUTPUT

Mode Selector

 

Open Circuit

 

 

Switch

Fine Control

Voltage

Load Volts

Load Amps

30-575 Setting

Maximum

75 - 80

39.5 - 42.0

575 - 585

 

 

 

 

 

PIPE MODES SHORT CIRCUIT CURRENT

(FINE CONTROL AT MAXIMUM)

Selector Position

Short Circuit Current (Amps)

90

127 - 140

150

215 - 230

200

310 - 330

350

545 - 575

500

640 - 660

 

 

WELDER CV (WIRE) OUTPUT

 

Mode Selector

 

Open Circuit

 

 

 

Switch

Fine Control

Voltage

Load Volts

Load Amps

 

CV - Wire

Maximum

75 - 78

39 - 42

520 - 535

 

CV - Wire

Maximum

NA

48 - 49

20

 

CV - Wire

Minimum

23 - 25

13 - 14

20

 

 

 

 

 

 

COMMANDER 500

Page 135
Image 135
Lincoln Electric SVM153-A service manual Retest After Repair, Engine RPM, Welder DC Stick Output, Welder CV Wire Output