TROUBLESHOOTING & REPAIR

STATOR VOLTAGE TEST (CONTINUED)

FIGURE F.15 – AUXILIARY LEAD TEST LOCATION

AUXILIARY LEADS #5B, #5E, #8, #9, #11, #12

(BEHIND PANEL)

Return to Section TOC

Return to Master TOC

AUXILIARY POWER AND WELD WINDINGS TEST

1.Start the engine and run at high idle (1900 RPM). Do not load welding or auxiliary power.

2.Check for 115-132VAC at leads #9 to #5B. Also check for 115-132VAC from leads #8 to #5E. See Figure F.15 and the Wiring Diagram.

3.Check for 230 to 264VAC at leads #11 to #12. See Figure F.15 and the Wiring Diagram.

Return to Section TOC

Return to Master TOC

COMMANDER 500