F-83

 

TROUBLESHOOTING & REPAIR

 

F-83

 

 

 

 

 

 

 

 

 

RETEST AFTER REPAIR (CONTINUED)

 

 

 

 

 

 

 

TOUCH START TIG MODE OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode Selector

 

 

 

 

Open Circuit

 

 

Short Circuit

 

Switch

 

 

Fine Control

Voltage

 

 

 

Current

 

TIG 20 - 250 A

 

 

 

Maximum

14.0 - 15.8

 

 

 

25 - 27

 

TIG 20 - 250 A

 

 

 

Minimum

12.0 - 13.8

 

 

 

21 - 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUXILIARY POWER OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

230 Volt Receptacle

115 Volt Receptacles

 

Open Circuit

 

 

 

 

 

Open Circuit

 

 

 

 

 

 

Voltage

 

Load Volts

 

Load Amps

Voltage

 

Load Volts

 

Load Amps

 

245 - 254

 

225 - 240

 

50

118 - 132

 

112 - 128

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 