C-5

C-5

ACCESSORIES

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

CONNECTION OF THE LN-7 TO THE COMMANDER 500 USING K584 OR K594 INPUT CABLE ASSEMBLY (SEE FIGURE C.2.)

1.Shut the welder off.

2.Connect the electrode cable from the LN-7 to the “+” terminal of the welder. Connect the work cable to the “-” terminal of the welder.

NOTE: Welding cable must be sized for current and duty cycle of application.

NOTE: Figure C.2 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the Commander 500 output terminals.

3.Connect the K584-XX or K594-XX Input Cable Assembly to the LN-7.

4.Connect the K584-XX or 594-XX input cable assembly to the 14-pin amphenol on the Commander 500.

5.Place the IDLER switch in the HIGH position.

CAUTION

Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control cir- cuits may be damaged. The engine governor setting is preset at the factory—do not adjust above RPM speci- fications listed in this manual.

6.Set the VOLTMETER switch to “+” or “-” depend- ing on the polarity chosen.

7.Set the OUTPUT RANGE switch toWIRE WELD-

ING CV.

7.Set the WELDING TERMINALS switch to WELD-

ING TERMINALS REMOTELY CONTROLLED.

9.Adjust wire feed speed at the LN-7.

10.Adjust the ARC CONTROL to the desired level (“soft” or “crisp”).

NOTE: For remote control, a K857 or K857-1 remote control is required. Connect it to the 6-pin amphenol.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE C.2

COMMANDER 500/LN-7 WITH K584 OR K594 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM

 

 

TO LN-7 INPUT

6 PIN

 

CABLE PLUG

AMPHENOL

 

K584 OR K594 CONTROL CABLE

 

 

 

 

OPTIONAL K857

 

 

REMOTE CONTROL

14 PIN

+

AMPHENOL

 

 

 

 

TO WORK

ELECTRODE CABLE

TO WIRE FEED UNIT

COMMANDER 500

Page 31