TROUBLESHOOTING & REPAIR

STATOR VOLTAGE TEST (CONTINUED)

FIGURE F.16 – OUTPUT RECTIFIER DIODE BRIDGE

W6W1

W2

W3

W4

W5

WELD WINDING

LEAD CONNECTIONS

Return to Section TOC

Return to Master TOC

4.Locate the weld winding leads connected to the three-phase output rectifier diode bridge. See Figure F.16.

5.Check for approximately 68VAC from W1 to W2. Also check from W3 to W4 and from W5 to W6.

6.If any of these voltages are low or missing perform the Flashing and Rotor Voltage Test and also the Rotor Resistance Test.

7.Also check leads #6F and #5P for loose or faulty connections to the field bridge. See the Wiring Diagram.

8.If the tests in Steps 6 and 7 are OK and the stator voltages are low or missing, the stator may be faulty.

9.Replace the lower front panel and output leads.

10.Replace the upper control panel and secure.

11.Replace the front left and right case sides.