Return to Section TOC

Return to Section TOC

to Section TOC

Return to Master TOC

Return to Master TOC

to Master TOC

F-32

F-32

 

 

TROUBLESHOOTING & REPAIR

FLASHING AND ROTOR VOLTAGE TEST(CONTINUED)

FIGURE F.11 – PLUG P/J52 LOCATION

PLUG P/J52

 

FILTER

 

 

 

 

FIELD DIODE

 

CAPACITOR

 

 

 

RECTIFIER BRIDGE

 

 

 

 

PLUG P/J52

 

 

 

9

10 11 12 13 14 15 16

 

1

2

3

4

5

6

7

8

 

LEAD # 200A

 

 

 

 

 

 

 

 

 

LEAD # 201A

 

 

 

 

 

 

 

 

 

Return

Return to Section TOC

Return

Return to Master TOC

TEST PROCEDURE

1.Using the 3/8" wrench, remove the sheet metal screws from the right front case side.

2.Carefully remove the right case side.

3.Set the volt/ohmmeter to the DC volts position.

4.Locate Plug P/J52 and leads #200A and #201A. See Figure F.11.

NOTE: Cut any cable ties necessary to perform the test. DO NOT UNPLUG PLUG P/J52.

5.Connect the positive meter probe to lead #200A and the negative meter probe to lead #201A.

6.Start the engine and run it at high idle speed (1900 RPM). Check the voltage reading on the meter. It should read approximately 16 VDC.

COMMANDER 500

Page 85
Image 85
Lincoln Electric SVM153-A service manual 10 11 12 13 14 15, Lead # 201A