Lincoln Electric SVM153-A service manual Check Igbt For Shorts

Models: SVM153-A

1 156
Download 156 pages 27.22 Kb
Page 101
Image 101

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-48

F-48

 

 

TROUBLESHOOTING & REPAIR

POWER MODULE TEST (CONTINUED)

FIGURE F.22 – IGBT TEST

HEAT SINK

POSITIVE (+)

CAPACITOR

TERMINAL

CONNECTIONS

Check IGBT For "Shorts"

 

7. Using the analog ohmmeter, connect the

8. Reverse the meter probe leads. The resis-

positive meter probe to the heat sink and the

tance should be very high (over 50,000

negative meter probe to the positive capaci-

ohms). It the resistance is low in either Step

tor terminal on the Power Module PC board.

7 or 8, the IGBT may be shorted or leaky.

See Figure F.22. The resistance reading

 

should be high (over 20,000 ohms).

 

COMMANDER 500

Page 101
Image 101
Lincoln Electric SVM153-A service manual Check Igbt For Shorts