C-8

C-8

ACCESSORIES

Return to Section TOC

Return to Section TOC

CONNECTION OF THE LN-23P TO THE COMMANDER 500 USING K350-1 ADAPTER (SEE FIGURE C.5.)

1.Shut the welder off.

2.Connect the electrode cable from the LN-23P to the “-” terminal of the welder. Connect the work cable to the “+” terminal of the welder.

NOTE: Welding cable must be sized for current and duty cycle of application.

NOTE: Figure C.5 shows the electrode connected for negative polarity.

3.Connect the K350-1 adapter to the amphenol on the LN-23P and the 14-pin amphenol of the Commander 500 as indicated in Figure C.5.

4.Place the IDLER switch in the HIGH position.

CAUTION

Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor set ting is preset at the factory—do not adjust above RPM specifications listed in this manual.

5.Set the VOLTMETER switch to negative.

6.Set the OUTPUT RANGE switch to WIRE WELD-

ING CV.

7.Set the WELDING TERMINALS switch to WELD-

ING TERMINALS REMOTELY CONTROLLED.

8.Adjust wire feed speed and voltage at the LN-23P.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIGURE C.5

COMMANDER 500/LN-23P CONNECTION DIAGRAM

COMMANDER 500 WITH 115 VAC AUXILIARY

14 PIN AMPHENOL

9 CONDUCTOR ADAPTER CABLE

K350-1

ELECTRODE

TO

 

 

 

 

 

 

 

 

 

 

 

WORK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LN-23P ADAPTER KIT

 

 

 

 

 

 

FEEDER "A"

 

 

FEEDER "B"

 

 

602

604

75

76

77

521

602

604

75

76

77

521

LN-23P

LN-23P

WORK

 

ELECTRODE

WIRE FEEDER "A"

ELECTRODE

WIRE FEEDER "B"

COMMANDER 500

Page 34
Image 34
Lincoln Electric SVM153-A service manual Figure C.5 Commander 500/LN-23P Connection Diagram