F-59

F-59

 

 

TROUBLESHOOTING & REPAIR

SHUTDOWN SOLENOID REMOVAL AND REPLACEMENT (CONTINUED)

FIGURE F. 25 – SHUTDOWN SOLENOID LEAD CONNECTIONS

PULL-IN COIL (LARGER TERMINALS EACH SIDE

#232M AND #265)

SHUTDOWN

SOLENOID

 

HOLD-IN COIL

IDLER

(SMALLER TERMINALS

EACH SIDE

SOLENOID

#224 AND #262)

PROCEDURE

1.Turn engine off.

2.Unlatch, lift and secure the engine access door.

3.Locate and remove the four spade connec- tors that attach the shutdown solenoid termi- nals to the wiring harness leads (#224, #232M, #265 and #262). See Figure F.25. Cut the cable tie.