B-12

B-12

OPERATION

TABLE B.4 – COMMANDER 500 SIMULTANEOUS WELDING AND POWER LOADS

 

 

Permissible

Permissible Auxiliary

Welding

 

Power - Watts

Current in Amperes

Output Range

 

(Unity Power

 

 

 

 

 

Setting

Welding Output

Factor)

@ 120 V ± 10%*

@ 240 V ± 10%*

 

 

 

 

 

30-575

500A/40V

0

0

0

500

500A/40V

0

0

0

350

350A/30V

9500

80*

40

250

250A/29V

12000

100**

50

150

150A/27V

12000

100**

50

90

90A/25V

12000

100**

50

 

 

 

 

 

*Each duplex receptacle is limited to 20 amps.

**Not to exceed 50 A per 120 VAC branch circuit when splitting the 240 VAC output.

EXTENSION CORD

RECOMMENDATIONS

An extension cord can be used with the auxiliary power outputs as long as it is of ample size. Table B.5 lists permissible extension cord lengths based on conduc- tor size and auxiliary power output.

TABLE B.5 – COMMANDER 500 EXTENSION CORD LENGTH RECOMMENDATIONS

Current

Voltage

Load

 

 

Maximum Allowable Cord Length in ft. (m) for Conductor Size

 

 

(Amps)

(Volts)

(Watts)

 

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

 

4 AWG

15

120

1800

 

30

(9)

40

(12)

75

(23)

125

(38)

175

(53)

 

300

(91)

15

240

3600

 

60

(18)

75

(23)

150

(46)

225

(69)

350

(107)

 

600

(183)

20

120

2400

 

 

 

30

(9)

50

(15)

88

(27)

138

(42)

 

225

(69)

20

240

48010

 

 

 

60

(18)

100

(30)

175

(53)

275

(84)

 

450

(137)

25

240

6000

 

 

 

 

 

90

(27)

150

(46)

225

(69)

 

250

(76)

30

240

7200

 

 

 

 

 

75

(23)

120

(37)

175

(53)

 

300

(91)

38

240

9000

 

 

 

 

 

 

 

100

(30)

150

(46)

 

250

(76)

50

240

12000

 

 

 

 

 

 

 

 

 

125

(38)

 

200

(61)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conductor size is based on maximum 2.0% voltage drop.