Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-10

 

 

 

 

 

 

F-10

TROUBLESHOOTING & REPAIR

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

 

 

 

The engine shuts down shortly

1.

Check for adequate fuel supply.

1.

Check the RUN/STOP switch

after starting.

2.

If any indicator light is lit when

 

and associated leads for loose

 

 

or faulty connections.

 

 

the engine shuts down, that par-

 

 

 

 

 

 

 

 

 

 

 

ticular system has faulted.

2.

Perform

the

Shutdown

 

 

Check system.

 

Solenoid Test.

 

 

 

3. Check the battery cables for

3.

The Peripheral PC board may

 

 

loose or faulty connections.

 

be faulty.

With the RUN/STOP

 

 

 

 

switch in the "RUN" position, the

 

 

 

 

Peripheral PC board should nor-

 

 

 

 

mally supply 10VDC to the shut-

 

 

 

 

down solenoid via leads #224

 

 

 

 

and #262. See the Wiring

 

 

 

 

Diagram.

 

 

 

 

 

 

 

4.

See the Engine Starting Diag-

 

 

 

 

nostic Chart.

 

 

 

 

 

 

 

 

 

 

 

 

The engine will not idle down to low

1.

Make sure the IDLER switch is

1.

Perform

the

Idler

Solenoid

speed. The machine has normal

 

in the "AUTO" position.

 

Test.

 

 

 

 

weld output and auxiliary power.

2. Make sure there is NOT an

2.

Check leads

#227, #232L,

 

 

 

external load on the weld termi-

 

#232M and #226A for loose or

 

 

nals nor the auxiliary power

 

faulty connections.

See the

 

 

receptacles.

 

Wiring Diagram.

 

 

 

3. Check for mechanical restric-

3.

The Pull Coil PC board may be

 

 

tions in the solenoid linkage.

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

COMMANDER 500

Page 63
Image 63
Lincoln Electric SVM153-A service manual Shutdown