CONNECTION OF THE LN-7 TO THE COMMANDER 500 USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.1.)

1.Shut the welder off.

2.Connect the electrode cable from the LN-7 to the “+” terminal of the welder. Connect the work cable to the “-” terminal of the welder.

NOTE: Welding cable must be sized for current and duty cycle of application.

CAUTION

Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control cir- cuits may be damaged. The engine governor setting is preset at the factory—do not adjust above RPM speci- fications listed in this manual.

Return to Section TOC

NOTE: Figure C.1 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the Commander 500 output terminals.

3.Connect the K867 Universal Adapter to the K291 or K404 input cable and the 14-pin amphenol of the Commander 500 as indicated in Figure C.1. Make the proper connections for local or remote control according to Figure C.1.

4.Connect the K291 or K404 input cable to the LN-7.

5.Place the IDLER switch in the HIGH position.

6.Set the VOLTMETER switch to “+” or “-” depend- ing on the polarity chosen.

7.Set the OUTPUT RANGE switch to WIRE WELD-

ING CV.

8.Set the WELDING TERMINALS switch to WELD-

ING TERMINAL REMOTELY CONTROLLED.

9.Adjust wire feed speed at the LN-7.

10.Adjust the ARC CONTROL to the desired level (“soft” or “crisp”).

Return to Master TOC

Return to Master TOC

FIGURE C.1

COMMANDER 500/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM

Return to Section TOC

Return to Master TOC

14 PIN AMPHENOL

+

SPARE

 

82

 

81

LN-7

WIRE

42

FEEDER

 

41

 

 

 

31

31

 

 

32

32

 

 

2

2

 

 

4

4

 

K867 UNIVERSAL

21

21

K291 OR K404

GND

 

GND

INPUT CABLE

ADAPTER PLUG

 

 

 

GREEN

Return to Section TOC

Return to Master TOC

TO WORK

75

75

ELECTRODE CABLE

76

76

77

77

TO WIRE FEED UNIT

 

K775 OPTIONAL

 

 

REMOTE CONTROL

COMMANDER 500

Page 30
Image 30
Lincoln Electric SVM153-A service manual To Work Electrode Cable To Wire Feed Unit