Lincoln Electric SVM153-A service manual Rotor Resistance Test, Test Description

Models: SVM153-A

1 156
Download 156 pages 27.22 Kb
Page 82
Image 82

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-29

F-29

 

 

TROUBLESHOOTING & REPAIR

ROTOR RESISTANCE TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

TEST DESCRIPTION

This test will determine if there is a shorted winding in the rotor or if the rotor is grounded.

MATERIALS NEEDED

Ohmmeter

3/8" Wrench or socket wrench

This procedure should take approximately 15 minutes to perform.

COMMANDER 500

Page 82
Image 82
Lincoln Electric SVM153-A service manual Rotor Resistance Test, Test Description