NORMAL TIG MODE VOLTAGE WAVEFORM

LOADED TO 200A 16 VOLTS

0 volts

10V50ms

This is the typical TIG MODE output voltage generated from a properly operating machine. Note that each vertical division represents 10 volts and that each horizontal division rep- resents 50 microseconds in time.

The machine was loaded with a resis- tance grid bank to 200 amps at 16 VDC.

SCOPE SETTINGS

Volts/Div

10V/Div.

Horizontal Sweep ...

50 ms/Div.

Coupling

DC

Trigger

Internal

 

 