y fet Sa
Maintenance and Servicing
Procedures not specifically explained in this manual must be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Squeeze and release the Trigger and unplug the tool from its electrical outlet before performing any procedure in this section.
To prevent serious injury from tool failure:
Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
Setup
no rati Ope
ec
Maintenan
1.BEFORE EACH USE, inspect the general condition of the tool. Check for:
•loose hardware,
•misalignment or binding of moving parts,
•cracked or broken parts,
•damaged electrical wiring, and
•any other condition that may affect its safe operation.
2.After Use, wipe external surfaces of the tool with clean cloth.
3.Periodically blow dust and grit out of the motor vents using dry compressed air. Wear ANSI‑approved safety goggles and NIOSH‑approved
breathing protection while doing this.
4.Check the condition of Blades regularly. Bent, cracked, worn or dull blades will not operate properly and can cause damage or injury. Discard damaged or worn blades.
5.WARNING! If the supply cord of this power tool is damaged, it must be replaced only by a qualified service technician.
Page 12 | For technical questions, please call | Item 65570 |