the drip plate (see figure 6).
figure 6
5Place bowl on the unit. Wet the gasket for ease of insertion.
Please take care that the hook on the backside of the bowl be inserted properly in its seat on the upper drip plate. (see figure 7).
figure 7
6Use fresh product to chase any remaining sanitizer from the bowl(s). Drain this solution. Do not rinse out the machine.
5. 4 IN-PLACE SANITIZATION
The
1Prepare two gallons of a warm
120
2Pour the solution into the bowl(s).
3Using a brush suitable for the purpose, wipe the solution on all surfaces protruding above the
4Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two minutes. Drain the solution out of the bowl(s).
5Use fresh product to chase any remaining sanitizer from the bowl(s). Drain this solution. Do not rinse out the machine.
6ROUTINE MAINTENANCE
Daily: inspect the machine for signs of product leaks past seals and gaskets. If proper assembly does not stop leaks around seals or gaskets, check for improper lubrication, worn or damaged parts. Replace parts as needed with original spare parts from the supplier.
6.1 MAINTENANCE (TO BE CARRIED OUT BY QUALIFIED SERVICE PERSONNEL ONLY)
Montly: clean all internal components, primarily the condenser, using compressed air.
To clean these internal parts, unplug the unit or switch off the
Condenser fins are very sharp. Use extreme caution when cleaning.
6