5. 3. 3 SANITIZING

1Prepare at least two gallons of a mild cleaning solution of warm (45-60 °C 120-140 °F) potable water and dishwashing detergent. Do not use abrasive detergent.

Important: if present, follow label directions, as too strong a solution can cause parts damage, while too mild a solution will not provide

adequate cleaning.

IMPORTANT

In order to prevent any damages to the dispenser use only a detergent suitable with plastic parts.

2Using a brush, suitable for the purpose, thoroughly clean all disassembled parts in the

cleaning solution.

ATTENTION

When cleaning the machine, do not allow excessive amounts of water around the electrically operated components of the unit. Electrical shock or damage to the machine may result.

3Do not immerse the lighted top covers in liquid. Wash them apart with the cleaning solution. Carefully clean their undersides.

4In the same manner clean the evaporator cylinder(s) using a soft bristle brush.

5Rinse all cleaned parts with cool clean water.

5. 3. 3 SANITIZING

Daily: Sanitizing should be performed immediately prior to starting the machine. Do not allow the unit to sit for extended periods of time after sanitization.

1Wash hands with a suitable antibacterial soap.

2Prepare at least two gallons of a warm (45-

60°C 120-140 °F) sanitizing solution (100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with two litres of water) according to your local Health Codes and manufacturer’s specifications.

3Place the parts in the sanitizing solution for five minutes.

4Do not immerse the lighted top covers in liquid. Carefully wash their undersides with the sanitizing solution.

5Place the sanitized parts on a clean dry surface to air dry.

6Wipe clean all exterior surfaces of the unit. Do not use abrasive cleaner.

5. 3. 4 ASSEMBLY

1Slide the drip tray into place.

2Pinch tube faucet: push the dispensing handle (1) and insert the pinch tube into its vertical seat in the bowl bottom(2). Lightly pull the pinch tube end downwards til itl is well arranged (3) (see figure 4).

figure 4

3Gravity faucet: install the faucet handle and the piston with its gasket (see figure 5).

figure 5

4Fit the bowl gasket to the evaporator. Note: the largest brim of the gasket must face against

5

Page 5
Image 5
Cecilware 8/4, 8/1 manual 5. 3. 3 SANITIZING, 5. 3. 4 ASSEMBLY