Troubleshooting
Problem |
| Possible Causes |
| Likely Solutions |
Tool will not start. | 1. | Cord not connected. | 1. | Check that cord is plugged in. |
| 2. | No power at outlet. | 2. | Check power at outlet. If outlet is |
|
|
|
| unpowered, turn off tool and check circuit |
|
|
|
| breaker. If breaker is tripped, make sure |
|
|
|
| circuit is right capacity for tool and circuit |
|
|
|
| has no other loads. |
| 3. | Internal damage or wear. (Carbon | 3. | Have technician service tool. |
|
| brushes or switch, for example.) |
|
|
Tool operates slowly. | 1. | Excess pressure applied to workpiece. | 1. Decrease pressure, allow tool to do the | |
|
|
|
| work. |
| 2. | Power being reduced by long or small | 2. | Eliminate use of extension cord. If an |
|
| diameter extension cord. |
| extension cord is needed, use one with |
|
|
|
| the proper diameter for its length and load. |
|
|
|
| See Extension Cords in GROUNDING |
|
|
|
| section. |
Performance | Carbon brushes worn or damaged. | Have qualified technician replace brushes. | ||
decreases over time. |
|
|
|
|
Excessive noise or | Internal damage or wear. (Carbon | Have technician service tool. | ||
rattling. | brushes or bearings, for example.) |
|
| |
Overheating. | 1. | Forcing tool to work too fast. | 1. | Allow tool to work at its own rate. |
| 2. | Blocked motor housing vents. | 2. | Wear |
|
|
|
| |
|
|
|
| while blowing dust out of motor using |
|
|
|
| compressed air. |
| 3. | Motor being strained by long or small | 3. | Eliminate use of extension cord. If an |
|
| diameter extension cord. |
| extension cord is needed, use one with |
|
|
|
| the proper diameter for its length and load. |
|
|
|
| See Extension Cords in GROUNDING |
|
|
|
| section. |
Tool does not sand | Disc accessory may be damaged, worn or | Check condition and type of disc accessory. | ||
effectively. | wrong type for the material. | Use only proper type of disc accessory in | ||
|
|
| good condition. |
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.