Chicago Electric 93881 operating instructions To Connect Electrical Loads

Models: 93881

1 20
Download 20 pages 5.7 Kb
Page 14
Image 14

To Connect Electrical Loads:

1.Start the Engine, and allow the Engine and Generator to run and warm up for five minutes after starting with no electrical load.

2.To Connect Electrical Loads: WARNING! Connect 120V AC appliances, tools, and equipment only to the two 120V AC Outlets. Connect 12V DC appliances, tools, and equipment only to the 12V DC Outlet. (See Figure E.)

3.Manual background CAUTION! Never exceed the rated capacity for this Generator, as serious damage to the Generator and/or appliances, tools, and equipment could result from an overload. Starting and running wattage requirements should always be calculated when matching this Generator’s wattage capacity to the appliance, tool, or equipment.

4.Most appliances, tools, and equipment will list on the motor nameplate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage:

Volts x AMP = Watts (example: 120 volts x 3 AMPs = 360 Watts)

5.To determine the approximate wattage requirement for most appliances, tools, and equipment with “inductive” type motors, multiply the wattage that was calculated by 2 times to assure adequate Generator capacity.

6.NOTE: The starting and running wattage for “resistant” loads are the same.

Example: a 100 Watt light bulb requires only 100 Watts to start. Most resistant loads will be listed in wattage.

7.Always power the largest electric motor first. Then, plug in other appliances, tools, and equipment one at a time.

A.Connect “inductive” load appliances, tools, and equipment first. Inductive loads consist of small hand tools and some small appliances. Connect the items that require the most wattage first.

B.Connect any lights next.

C.Voltage sensitive appliances, tools, and equipment should be the last to be

connected to the Generator. Plug voltage sensitive items such as T.V.’s, VCR’s,

®

microwaves, and cordless telephones into a UL listed voltage surge protector

®

(not included). Then, connect the UL Listed surge protector into the Generator.

8.Manual backgroundCAUTION! Failure to connect and operate appliances, tools, and equipment in this sequence can cause damage to the Generator, appliances, tools, and equipment and will void the warranty on this Generator.

SKU 93881 For technical questions, please call 1-800-444-3353 PAGE 14