Replacing the internal clock battery

This projector has internal clock that uses a battery. When the clock of the network function does not work correctly, please try solution by replacement of the battery: HITACHI MAXELL or HITACHI MAXELL ENERGY, part number CR2032 or CR2032H.

OPEN

CLOSE

 

1. Turn the projector off, and unplug the power cord. Allow the projector to cool suffi ciently.

2. After making sure that the projector has cooled adequately, slowly turn over the projector, so that the bottom is facing.

3. There is a raised dot near the battery cover at the bottom of the projector. Turn the cover in the direction indicated OPEN to position one end of the slit on the cover with the dot, using a coin or the like. And then pick the cover up to remove it.

Raised dot

Knob

Battery

Cover OPENCLOSE

EOSCL

OPEN

4. Pry up the battery using a fl athead screwdriver or the like to take it out. While prying it up, put a fi nger lightly on the battery since it may pop out of the holder.

5. Replace with a new battery of the specifi ed type. With

Battery

the plus side facing up, slide the battery under the claw of the spring fi tting. And press down on the battery until it snaps into place.

6. Replace the battery cover in place, then turn it in the direction indicated CLOSE to position the knob of the cover with the dot on the bottom case to fi x the cover, using a coin or the like.

CLOSE OPEN

NOTE • The internal clock will be initialized by removing the battery. For setting the clock, see the User Manual - Network Guide.

WARNING ►Be careful of handling a battery, as a battery can cause explosion, cracking or leakage, which could result in a fi re, an injury, and environment pollution.

Use only the specifi ed and perfect battery. Do not use a battery with damage, such as a scratch, a dent, rust or leakage.

When replacing the battery, replace it with a new battery.

When a battery leaked, wipe the leakage out well with a waste cloth. If the leakage adhered to your body, immediately rinse it well with water. When a battery leaked in the battery holder, replace the batteries after wiping the leakage out.

Make sure the plus and minus terminals are correctly aligned when loading a battery.

Do not work on a battery; for example recharging or soldering.

Keep a battery in a dark, cool and dry place. Never expose a battery to a fi re or water.

Keep a battery away from children and pets. Be careful for them not to swallow a battery. If swallowed consult a physician immediately for emergency treatment.

Obey the local laws on disposing a battery.