P 3 5 G P S D u a l L e n s T u r r e t P r o j e c t o r
7.2. ULTRAMITTENT ASSEMBLY
7 . 2 . 1 . SYMPTOM: E X C E S S I V E T I C K I N G
Excessive ticking is indicative of a worn star or cam. Replace Ultramittent assembly (see Section 5.4.6).
7 . 2 . 2 . SYMPTOM: E X C E S S I V E F I L M N O I S E
1.Check for improper gate tension. Use adjustment knob at top of gate assembly to correct gate tension.
2.Check for improper shoe closure or alignment.
3.If excessive film noise continues, problem may be caused by worn Ultramittent sprocket. Replace Ultramittent assembly (see Section 5.4.6).
7 . 2 . 3 . SYMPTOM: F I L M I N S T A B I L I T Y (J U M P )
1.Verify image alignment by running
2.Check for worn Ultramittent sprocket. There should be no sprocket movement when manual turndown knob (item 13 in Figure
7 . 2 . 4 . SYMPTOM: S H U T T E R S T R E A K I N G
Time shutter (see Section 6.5).
7.3. CONSTANT
The following paragraphs pertain to all three (upper, center, and lower)
7 . 3 . 1 . SYMPTOM: E X C E S S I V E N O I S E
1.Check for play in shaft or bearings. Adjust or replace as indicated.
2.Check for improperly aligned keeper or stripper. Realign as needed.
3.Check for loose pulley or sprocket. Tighten as needed.
7 . 3 . 2 . SYMPTOM: F I L M S P R O C K E T H O L E D A M A G E
Check for hooked or damaged sprocket. Replace as needed.
7 . 3 . 3 . SYMPTOM: S P R O C K E T R I D I N G
1. Check alignment of pad roller. Adjust as needed.