Module Configuration

Decommissioning a GRP card also decommissions all interfaces under that GRP card.

To decommission a module, proceed as follows:

Step 1 Open the Configuration window. Refer to the “Viewing the Configuration Window” section on page 5-3for further details.

Step 2 Choose a Chassis and Module from the list boxes displayed at the left of the window.

Step 3 Choose Decommission to decommission the selected module. An Action Report window appears confirming that the decommissioning action was completed successfully.

Figure 5-3 Action Report Window

Step 4 Choose Close to close the Action Report window.

The selected module is now decommissioned. Decommissioning a GRP or any supporting module initiates the following activities:

Heartbeat polling stops on the object

The state is changed to decommissioned

Status data is no longer available

Performance polling stops on the module (if enabled)

Decommissioning a line card initiates the following activities:

All interfaces and ATM connections on the line card are also decommissioned

Heartbeat polling stops on the line card and interfaces

The line card, interfaces, and ATM connections are placed in the decommissioned state

Status data is no longer available on the line card and interfaces

Cisco 12000/10700 v3.1 Router Manager User Guide