4-5
Catalyst 2984G, 2948G-GE-TX, and 2980G Switch Hardware Installation Guide
78-6286-05
Chapter4 Configuring the Gigabit Etherne t Ports Installing, Removing, and Maintaining GBICs
GBIC Optical Power CharacteristicsTable 4 -3 provides the GBIC optical power charact eris tics .
Note For information about the Coarse Wave Division Multip lexing (CWDM), refer to
the Cisco CWDM GBIC and CWDM SFP Installation Note.
GBIC Cabling RestrictionsYou must observe the following fiber-optic cabling restrictions when using
GBICs:
•The minimum cabling distance for 1000BASE-SX and 1000BASE-LX/LH
GBICs is 6.5 feet (2 meters).
•The maximum cabling distance for each GBIC type is listed in Table 4-2 .
Table4-3 GBIC Optical Power Characteristics
Parameter 1000BASE-SX
(WS-G5484) 1000BASE-LX/LH
(WS-G5486) 1000BASE-ZX
(WS-G5487)
Transmitter output power
(min/max) 0/–9.5 dBm –3/–9.5 dBm 0/4.77 dBm
Receiver maximum input
power 0 dBm –3 dBm –3 dBm
Receiver sensitivity –17 dBm –19 dBm –23 dBm
Channel insertion loss
50/125 micron1 MMF
1. 1 micron (µ) equals 1 micrometer or 10-6 meters
3.4 dBm 4.4 dBm –
62.5/125 micron MMF 3.2 dBm 6 dBm –
9/10 micron SMF – 6.5 dBm 21.5 dBm