27-12
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
OL-10101-02
Chapter 27 Configuring SNMP
Configuring SNMP
You can use the snmp-server host global configuration command to a specific host to receive the
notification types listed in Table 27-4.
Beginning in privileged EXEC mode, configure the switch to send traps or informs to a host:
cluster Generates a trap when the cluster configuration changes.
config Generates a trap for SNMP configuration changes.
copy-config Generates a trap for SNMP copy configuration changes.
entity Generates a trap for SNMP entity changes.
envmon Generates environmental monitor traps. You can enable any or all of these
environmental traps: fan, shutdown, status, supply, temperature.
flash Generates SNMP FLASH notifications.
hsrp Generates a trap for Hot Standby Router Protocol (HSRP) changes.
mac-notification Generates a trap for MAC address notifications.
port-security Generates SNMP port security traps. You can also set a maximum trap rate
per second. The range is from 0 to 1000; the default is 0, which means that
there is no rate limit.
Note When you configure a trap by using the notification type
port-security, configure the port security trap first, and then
configure the port security trap rate:
snmp-server enable traps port-security
snmp-server enable traps port-security trap-rate rate
rtr Generates a trap for the SNMP Response Time Reporter (RTR).
snmp Generates a trap for SNMP-type notifications.
stpx Generates SNMP STP Extended MIB traps.
syslog Generates SNMP syslog traps.
tty Generates a trap for TCP connections. This trap is enabled by default.
vlancreate Generates SNMP VLAN-created traps.
vlandelete Generates SNMP VLAN-deleted traps.
vlan-membership Generates a trap for SNMP VLAN membership changes.
vtp Generates a trap for VLAN Trunking Protocol (VTP) changes.
Table 27-4 Switch Notification Types (continued)
Notification Type
Keyword Description
Command Purpose
Step 1 configure terminal Enter global configuration mode.
Step 2 snmp-server engineID remote
ip-address engineid-string
Specify the engine ID for the remote host.