2-9
Installation Guide for the Cisco Secure PIX Firewall Version 5.2
78-11180-01
Chapter2 Installing a PIX Firewall
Installing a PIX 515

Vertical Mounting

To mount the PIX 515 vertically, attach the brackets to the side of the unit and mount the unit vertically
as shown in Figure 2-8.
Figure 2-8 Installing the PIX 515 Vertically
PIX 515 Installation Steps
Use the following steps to install a PIX 515:
Step 1 Use the Console port to connect to a computer to enter configuration commands. Locate the serial cable
from the accessory kit. The serial cable assembly consists of a null modem cable with RJ-45 connectors,
and one DB-9 connector and a DB-25 connector. Connect the cable as shown in Figure2-9 so that you
have either a DB-9 or DB-25 connector on one end as required by the serial port for your computer, and
the other end is the RJ-45 connector.
Connect the RJ-45 connector to the PIX 515 Console port and connect the other end to the serial port
connector on your computer.
24303
DO NOT INSTALL INTERFACE
CARDS WITH POWER APPLIED
CONSOLE
10/100 ETHERNET 0/0
LinkFDXFDX
100 MbpsLink
100 Mbps
FAILOVER
10/100 ETHERNET 0/0
PIX-515