Using the ratcheting torque screwdriver,

Step 4

Using the ratcheting torque screwdriver,

 

 

 

torque each terminal block captive screw

 

 

 

(above the installed wire leads) to 4.5 lbf-in.

 

 

 

(72 ozf-in.).

Return

Feed A

 

 

 

 

Negative

 

 

 

 

 

Return

Feed B

 

 

Negative

 

 

 

Step 5

Insert the terminal block plug in the terminal

 

 

 

block header on the rear panel of the switch.

 

 

 

36 -

 

 

1

72V

 

 

- 0.5A

 

 

 

A

 

 

 

B

 

Step 6 Move the circuit-breaker handle for the DC power source to the on position.

Caution You must connect the Catalyst 3550-24-DC switch only to a DC-input power source that has an input supply voltage from –36 to –72 VDC. If the supply voltage is not in this range, the switch might not operate properly or might be damaged.