Assigning SCSI IDs
Figure 3 | Location of Drive Bays Behind the Bezel |
1
4
2
3
151556
1 | 2 | Flash memory card | |
|
|
|
|
3 | Drive bay 1 (right side of chassis front) | 4 | Drive bay 0 (left side of chassis front) |
|
|
|
|
|
|
|
|
Assigning SCSI IDs
When you install or replace one or more of the SCSI disk drives in a
To assign the proper SCSI ID to a disk drive, follow these steps:
Step 1 Set the SCSI IDs for your drive by placing jumpers on the appropriate jumper pins, as follows:
•Assign SCSI ID 0 to the disk drive in the first drive bay by removing any jumpers from the jumper pins.
The first drive bay (drive bay 0) is located below the
•Assign SCSI ID 1 to the disk drive in the second drive bay by placing a jumper on the pins closest to the power connector. Figure 4 shows the jumper placement for SCSI ID 1.
The second drive bay (drive bay 1) is located below the flash memory card on the right side of your system. (See Figure 3.)
Figure 4 shows the connector end of the hard disk drive and the location of the jumper pins.
Installing Hard Disk Drives in the Cisco Wide Area Application Engine 611
6 |
| |
|