Installing the MSFC2
Figure 7 Installing the Screws
SWITCH LOAD | PORT 1 | PORT 2 |
100%
SYSYEMCONSOLE | R | MGM | T | CONSOLE |
|
|
PW |
|
| RESET | PORT |
|
|
|
|
|
|
|
| |
|
|
|
| ,MODE |
|
|
|
|
| CONSOLE | PCMCIA | EJECT | 1% |
SUPERVISOR 2
63700
Step 7 Install the supervisor engine in the Catalyst 6000 family switch. (Refer to the Catalyst 6000 Family Module Installation Guide for installation instructions.)
Caution The hardware on both supervisor engines in a single chassis must be identical. If you have redundant supervisor engines, you must install an MSFC2 on each supervisor engine.
Step 8 If you are installing an MSFC2 on a redundant supervisor engine, go to Step 3 in the “Preparing the Supervisor Engine” section on page 7 and follow the procedure for removing the supervisor engine.
Step 9 Power up the switch.
Step 10 Depending on the software running on the switch, do one of the following steps to verify the installation:
•Cisco IOS for the Catalyst 6000 Family of Switches product on the supervisor engine and the MSFC2:
Verify that the switch is online. This indicates that the system acknowledges the new module and has brought it online.
•Catalyst supervisor engine software on the supervisor engine and Cisco IOS on the MSFC2:
Enter the show module command to verify that the system acknowledges the new module and has brought it online.
Catalyst 6000 Family Multilayer Switch Feature Card 2 Installation Note
| 13 |
| |
|
|