Dynacord DPA 4120 Checking the ground fault surveillance function, Fuses 11.1 Fuses in the DPA

Models: DPA 4120 DPA 4140

1 23
Download 23 pages 27.73 Kb
Page 17
Image 17

Checking the ground fault surveillance function:

When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light. Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for approximately 5 seconds to ground potential, the corresponding red GROUND FAULT indicator (6) has to light and the READY fault message relay of the INPUT MODULE NRS 90225 drops while the green READY indicator (7) stays lit. After releasing the button, the indication and the fault message are maintained. The TEST button (3) has to be used to reset the ground fault surveillance function. For further details on checking the function with the REMOTE MODULE NRS 90222 being included in your installation, please refer to the PROMATRIX handbook.

9.19"-case and 19“-rack-shelf system installation

Note

Operation of the power amplifiers DPA 4120 and DPA 4140 with enclosure cover plates detached is

 

strictly prohibited.

 

 

When mounting the power amplifiers within rack-cases or rack-shelf systems make sure to provide sufficient airflow. The space between the rear panel of the amplifier and the inner wall of the rack-case has to be at least 60 mm x 330

mm.A free space of at least 100 mm above the rack-shelf system is needed to provide sufficient air circulation. Since it is possible that during operation the temperature inside the rack system increases by 10° C, the maximum allowable ambient temperatures of the rest of the incorporated modules and appliances within a specific rack-shelf or rack-case have to be taken into careful consideration.

Note

To ensure trouble-free operation of the appliance, the maximum permissible ambient temperature of

 

+40°C is not to be exceeded.

 

 

10.Ground lift switch CIRCUIT TO CHASSIS SWITCH

The ground lift switch CIRCUIT TO CHASSIS SWITCH (19) provides the possibility to separate the signal ground from the enclosure (ground potential). This is mainly meant to eliminate noise-problems which are introduced through ground-loops, without jeopardizing the security. In case several appliances within a single rack-case or rack-shelf are furnished with ground lift switches, it is recommended to set all devices but one to "ungrounded“. Set one appliance to "grounded". When set to "ungrounded", the impedance between signal ground and enclosure is : 100 k ohms // 100 nF. It is needed to maintain EMV protection.

11.Fuses

11.1 Fuses in the DPA 4120

location

Pos.

purpose

value

dimensions

standard

fuse socket (11)

F601

mains fuse 230V~ AC

T2A

5x20 mm

IEC 127-2-3

fuse socket (11)

F601

mains fuse 115V~ AC

T4A

5x20 mm

IEC 127-2-3

printed board assembly

F602

mains fuse 100V - 250V

T1A

Ø 8.5xRM 5.08mm

IEC 127-3/4

86243

 

 

 

 

 

printed board assembly

F502

battery fuse 24V DC

15A

flat fuse

DIN 72581-3

85270

 

 

 

 

 

printed board assembly

F503

battery fuse 24V DC

15A

flat fuse

DIN 72581-3

85270

 

 

 

 

 

11.2 Fuses in the DPA 4140

 

 

 

 

location

Pos.

purpose

value

dimensions

standard

fuse socket (11)

F601

mains fuse 230V~ AC

T4A

5x20 mm

IEC 127-2-3

fuse socket (11)

F601

mains fuse 115V~ AC

T8A

5x20 mm

IEC 127-2-3

printed board assembly

F602

mains fuse 100V - 250V

T1A

Ø 8.5xRM 5.08mm

IEC 127-3/4

86243

 

 

 

 

 

printed board assembly

F502

battery fuse 24V DC

25A

flat fuse

DIN 72581-3

85268

 

 

 

 

 

printed board assembly

F503

battery fuse 24V DC

25A

flat fuse

DIN 72581-3

85268

 

 

 

 

 

39

Page 17
Image 17
Dynacord DPA 4120, DPA 4140 Checking the ground fault surveillance function, caseand 19“-rack-shelfsystem installation