POWER AMPLIFIER DPA 4120 / DPA 4140 | OWNER'S MANUAL |
DPA 4140
40 0 WATTS POWER AMPL IFIER
CLIPT EST
0dB
- 13dB
READYSTANDBY
GROUND | PROT ECT | |
FAULT | ||
|
Performance Features
Power amplifier with 200 W or 400 W output power according to the IEC
∙supported are 115/230V AC mains as well as 24V DC emergency power source
∙power amplifiers DPA 4120 providing 200 W or DPA 4140 providing 400 W output power, idling and
∙output transformer for balanced, floating 100 V speaker networks of optionally 70 V, 50 V or 4 ohms for
∙optional input modules:
standard operation INPUT MODULE with level control, electronically balanced input and MONITOR output with optional transformer or
REMOTE MODULE for controlling and monitoring the PROMATRIX system, electronic level controls, electronically balanced input and MONITOR output with optional transformer
∙integrated
∙mains POWER ON/OFF switch
∙ground lift switch
∙remotely controllable mains and battery operation with initial current inrush limiter
∙
∙
∙fault message according to the IEC 849 standard
∙TEST button to switch between system and average operation, respectively a RESET button to restart after the occurrence of ground fault conditions
∙LED level meter instrument with a display range of
∙integrated relays for single call and obligatory reception
∙active, temperature controlled ventilation
∙pilot tone and ground fault surveillance module according to the DIN/VDE 0800 standard (optional)