Dynacord extension kits for the DPA 4120 and DPA, 13.2NRS 90222 remote module, 13.5.2

Models: DPA 4120 DPA 4140

1 23
Download 23 pages 27.73 Kb
Page 23
Image 23

interfering voltage (A)

features of the monitor output: nominal output voltage nominal load impedance

ambient temperature range dimensions (W x H x D) depth with / without connections weight without extensions finish

£1.2 mV = -56 dBu electronically balanced 2 V = + 8.2 dBu

600 ohms

+5 °C .. +40 °C

483 x 132 x 345 mm max. 400 mm / 340 mm

16.7kg

anthracite

extension kits for the DPA 4120 and DPA 4140:

 

 

NRS 90208 input transformer for floating, balanced input

Art. No.

121 641

NRS 90222 remote module

Art. No.

121 674

NRS 90224 pilot tone & ground fault surveillance

Art. No.

121 676

NRS 90225 standard input module

Art. No.

121 677

NRS 90227 output transformer for floating, balanced monitor output

Art. No.

121 679

13.Extension kit specifications for the power amplifiers DPA 4120 / DPA 4140

13.1NRS 90225 standard input module see specifications DPA 4120 / DPA 4140

13.2NRS 90222 remote module

see specifications DPA 4120 / DPA 4140

13.3NRS 90208 input transformer for floating, balanced input

frequency response

20 Hz .. 20 kHz

input impedance

³ 10 k ohms

idling ratio

1:1

winding resistance; primary

1420 ohms at 20°C

winding resistance; secondary

1420 ohms at 20°C

13.4NRS 90227 output transformer for floating, balanced monitor output

frequency response

40 Hz .. 20 kHz

nominal load impedance

³ 600 ohms

idling ration

1:1

winding resistance; primary

18 ohms at 20°C

winding resistance; secondary

18 ohms at 20°C

13.5NRS 90224 pilot tone & ground fault surveillance

13.5.1 pilot tone surveillance

 

pilot tone frequency

19 kHz ± 1%

error recognition threshold

£ 12 mV

fault message output via NRS 90225

collective fault message via READY relay

fault message output via NRS 90222

PROMATRIX manager DPM 4000

13.5.2

ground fault surveillance

 

input

loudspeaker line 4 ohms / 50V / 70V / 100V

 

fault message output via NRS 90225

collective fault message via READY relay

fault message output via NRS 90222

PROMATRIX Manager DPM 4000

disruptive strength

1000 Veff

error recognition threshold

£ 50 k ohms

45

Page 23
Image 23
Dynacord extension kits for the DPA 4120 and DPA, 13.2NRS 90222 remote module, pilot tone surveillance, 13.5.2