Dynacord Specifications, 12.1DPA 4120 power amplifier 200 W, power supply, mains operation

Models: DPA 4120 DPA 4140

1 23
Download 23 pages 27.73 Kb
Page 21
Image 21

Caution For security reasons it is necessary to ensure that, after the installation is completed, all wiring located beneath the power supply input PCB are within a distance of at least 6 mm to the printed board assembly.

12.Specifications

12.1DPA 4120 power amplifier 200 W

power supply:

 

 

 

 

 

 

 

mains operation

 

 

 

115 V / 230 V~ AC, ±10 %

 

mains frequency

 

 

 

50 - 60 Hz

 

 

security class

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

mains operation

 

Umains / V

Imains / A

Pmains / VA

Pmains / W

Pout / W

Pv / W

idling

 

230

0.13

30

16

0

16

normal operation

(-10 dB)

230

0.83

191

138

20

118

alarm (-3 dB)

 

230

1.67

384

298

100

198

standard conditions

230

2.27

522

415

200

215

initial current inrush (mains)

 

< 29 A

 

 

 

 

 

 

 

 

 

 

 

 

mains operation

 

Umains / V

Imains / A

Pmains / VA

Pmains / W

Pout / W

Pv / W

idling

 

115

0.26

30

16

0

16

normal operation

(-10 dB)

115

1.67

191

138

20

118

alarm (-3 dB)

 

115

3.34

384

298

100

198

standard conditions

115

4.54

522

415

200

215

initial current inrush (mains)

 

< 20 A

 

 

 

 

Pmains / VA = apparent power Umains*Imains; Pmains / W = true power;

Pout / W = output power; Pv / W =leakage power

battery operation

 

 

 

 

24 V DC,

-10/+30 %

 

 

 

 

 

 

 

 

 

battery operation

UB / V

 

IB / A

 

Pi / W

Pout / W

Pv / W

stand-by

24

 

2.5m

 

60m

0

60m

idling

24

 

0.43

 

10

0

10

normal operation (-10 dB)

24

 

3.74

 

90

20

90

standard conditions

24

 

9.10

 

218

131

87

initial current inrush (battery)

 

 

< 3.8 A

 

 

 

Pi / W = input power UB*IB; Pout / W = output power;

Pv / W = leakage power

 

 

features of the input: nominal input level nominal input impedance

features of the power output:

nominal output capacity during mains operation nominal load impedance

frequency response

distortion at 1 kHz and nominal output power interfering voltage (A)

features of the monitor output: nominal output voltage nominal load impedance

electronically balanced 775 mV = 0 dBu

³10 k ohms balanced, floating

200 W (according to IEC 268-3)

50 ohms / 100V; 25 ohms / 70 V; 12.5 ohms / 50 V or 4 ohms / 28 V

60 Hz .. 20 kHz £ 1 %

£ 1.2 mV = -56 dBu electronically balanced 2 V = + 8.2 dBu

600 ohms

43