Caution For security reasons it is necessary to ensure that, after the installation is completed, all wiring located beneath the power supply input PCB are within a distance of at least 6 mm to the printed board assembly.
12.Specifications
12.1DPA 4120 power amplifier 200 W
power supply: |
|
|
|
|
|
|
|
mains operation |
|
|
| 115 V / 230 V~ AC, ±10 % |
| ||
mains frequency |
|
|
| 50 - 60 Hz |
|
| |
security class |
|
|
| I |
|
|
|
|
|
|
|
|
|
|
|
mains operation |
| Umains / V | Imains / A | Pmains / VA | Pmains / W | Pout / W | Pv / W |
idling |
| 230 | 0.13 | 30 | 16 | 0 | 16 |
normal operation | 230 | 0.83 | 191 | 138 | 20 | 118 | |
alarm |
| 230 | 1.67 | 384 | 298 | 100 | 198 |
standard conditions | 230 | 2.27 | 522 | 415 | 200 | 215 | |
initial current inrush (mains) |
| < 29 A |
|
|
|
| |
|
|
|
|
|
|
|
|
mains operation |
| Umains / V | Imains / A | Pmains / VA | Pmains / W | Pout / W | Pv / W |
idling |
| 115 | 0.26 | 30 | 16 | 0 | 16 |
normal operation | 115 | 1.67 | 191 | 138 | 20 | 118 | |
alarm |
| 115 | 3.34 | 384 | 298 | 100 | 198 |
standard conditions | 115 | 4.54 | 522 | 415 | 200 | 215 | |
initial current inrush (mains) |
| < 20 A |
|
|
|
|
Pmains / VA = apparent power Umains*Imains; Pmains / W = true power; | Pout / W = output power; Pv / W =leakage power | ||||||
battery operation |
|
|
|
| 24 V DC, |
| |
|
|
|
|
|
|
|
|
battery operation | UB / V |
| IB / A |
| Pi / W | Pout / W | Pv / W |
24 |
| 2.5m |
| 60m | 0 | 60m | |
idling | 24 |
| 0.43 |
| 10 | 0 | 10 |
normal operation | 24 |
| 3.74 |
| 90 | 20 | 90 |
standard conditions | 24 |
| 9.10 |
| 218 | 131 | 87 |
initial current inrush (battery) |
|
| < 3.8 A |
|
|
| |
Pi / W = input power UB*IB; Pout / W = output power; | Pv / W = leakage power |
|
|
features of the input: nominal input level nominal input impedance
features of the power output:
nominal output capacity during mains operation nominal load impedance
frequency response
distortion at 1 kHz and nominal output power interfering voltage (A)
features of the monitor output: nominal output voltage nominal load impedance
electronically balanced 775 mV = 0 dBu
³10 k ohms balanced, floating
200 W (according to IEC
50 ohms / 100V; 25 ohms / 70 V; 12.5 ohms / 50 V or 4 ohms / 28 V
60 Hz .. 20 kHz £ 1 %
£ 1.2 mV =
600 ohms
43