C H A P T E R 3

Troubleshooting

Table 3-1describes how to identify problems with the switch and GigaStack

GBIC and how to resolve them.

Table 3-1 Common Problems and Their Solutions

 

Symptom

Possible Causes

Corrective Action

 

 

 

 

 

GBIC module slot

Spanning Tree Protocol

Wait for STP to complete its search. The LED

 

LED is amber.

(STP) is checking for loops.

turns green when STP completes its check.

 

 

Port is initializing, it was

Use the Cluster Management Suite or the IOS

 

 

disabled by management or

command-line interface to check the status of the

 

 

an address violation, or it

port and to enable it.

 

 

was blocked by STP.

 

 

 

 

 

 

 

 

GBIC module slot

Port is experiencing error

Remove and reinsert the GigaStack GBIC.

 

LED is flashing

frames. This could be due to

 

 

 

 

green and amber.

a duplex mismatch caused

 

 

 

 

 

by autonegotiation,

 

 

 

 

 

collisions, cyclic

 

 

 

 

 

redundancy check (CRC)

 

 

 

 

 

errors, or alignment errors.

 

 

 

 

 

 

 

 

GBIC module slot

Device has no power.

Ensure that the switch and the target device have

 

LED is off.

 

power.

 

 

No link or port was shut

Verify that the GBIC cable is connected to another

 

 

down administratively.

active network device and that the port is not shut

 

 

 

down.

 

 

Bad cable.

Replace with a known good cable.

 

 

 

 

 

 

 

 

Catalyst GigaStack Gigabit Interface Converter Hardware Installation Guide

 

 

 

 

 

 