4-2
Catalyst 4500 E-Series Switches Installation Guide
OL-13972-01
Chapter 4 Removing and Replacing FRUs
Removing and Replacing the Power Supply
Removing and Replacing the Power Supply
This section describes how to remove and install the AC-input power supply and DC-input power supply
for the Catalyst 4500 E-series switches. This information is presented in the following sections:
Required Tools, page 4-4
Removing an AC-Input Power Supply, page 4-4
Installing an AC-Input Power Supply, page 4-6
Removing a DC-Input Power Supply, page 4-8
Installing a DC-Input Power Supply, page 4-11
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing.
Statement 1034
Figure 4-1 and Figure 4-2 show the AC-input power supplies. Figure 4-3 and Figure 4-4 show a the
DC-input power supplies. Locate your power supply and notice the location of the captive installation
screws.
Note The power supplies are hot-swappable, so in redundant mode you will not need to power down the switch
to replace or upgrade most power supplies. In combined mode som e slots may lose power during an
upgrade or power supply replacement.
Figure 4-1 AC-Input Power Supply
1AC recepta cle 3Captive screws
2Power switch
231375
1
2
3