2Printer Operation

Mode Settings

[Zebra® Emulation]

Top Menu

Sub Menu

Default

Menu

Remarks

 

 

 

 

 

After Print

AutoConfigure

On

On

Optional auto configure

 

 

 

Off

On .... Auto configure effective.

 

 

 

 

If a peeler unit or auto-cutter is

 

 

 

 

installed, each mode is automatically

 

 

 

 

set regardless of the “function select”

 

 

 

 

setting.

 

 

 

 

Off ... Auto configure ineffective.

 

 

 

 

When a peeler unit or auto-cutter is

 

 

 

 

installed but has not been started, it is

 

 

 

 

off and the operation is selected by

 

 

 

 

“Function select”.

 

 

 

 

 

 

Function Select

Tear

Off

Selects the type of options installed and

 

 

 

Tear

adjusts the "paper stop" position accordingly.

 

 

 

Peel On*

For example, the position where the label

 

 

 

Cut On*

stops in "Tear" mode is different to that in

 

 

 

 

"Peel On" mode.

 

 

 

 

 

 

Cutter Action*

Backfeed

Backfeed

Cutter operating method setting

 

 

 

Through

Backfeed: it feeds back after each cutting

 

 

 

 

operation.

 

 

 

 

Through: when the number copied = n, the

 

 

 

 

back end of sheet 1 to n-1 passes through,

 

 

 

 

and the back end of the final page that is a

 

 

 

 

single sheet is copied and fed back.

Paper Position

0.00IN

Peel/Cut/Tear Off

 

0.00mm

0.00 to 2.00 IN

 

 

0.0 to 50.8mm

 

 

Peel/Cut/Tear On

 

 

-1.00 to 1.00 IN

 

 

-25.4 to 25.4mm

The stop position can be fine tuned using this menu setting. The general stop position is selected depending on the "Function" selected above.

 

Mode/Repeat Key

Disabled

LabelSet

Repeat method selection

 

 

 

LastOne

LabelSet:

 

 

 

Disabled

Reissues multiple labels.

 

 

 

 

LastOne:

 

 

 

 

Issues only the final page.

 

 

 

 

In count case, it issues only 1 label while

 

 

 

 

continuing.

 

 

 

 

Disabled:

 

 

 

 

Makes the repeat key invalid.

 

 

 

 

 

Interface

RS-232C Baud

9600

115200

Sets the baud rate of the serial interface.

 

 

 

57600

• Interface related settings are effective

 

 

 

38400

after the power is turned on again.

 

 

 

19200

 

 

 

 

9600

 

 

 

 

4800

 

 

 

 

2400

 

 

RS-232C Parity

None

None

Sets the communication parity of the serial

 

 

 

Odd

interface.

 

 

 

Even

 

 

 

 

 

 

 

RS-232C Length

8 bits

8 bits

Sets the character length of the serial

 

 

 

7 bits

interface.

 

 

 

 

 

 

RS-232C Stop bit

1 bit

1 bit

Sets the stop bit of the serial interface.

 

 

 

2 bits

 

 

 

 

 

 

 

RS-232C X-ON

Yes

Yes

Selects the X-ON flow control of the serial

 

 

 

No

interface.

 

 

 

 

 

 

IEEE1284

ON

ON

Enable or disables the 'enhanced' features of

 

 

 

OFF

the IEEE1284 parallel interface.

 

 

 

 

 

* Effective only when the optional unit is attached.