Menu Setting Table
Page Setup Menu - allows you to change settings related to the media or print quality.
System Setup Menu - allows you to change settings for the printer hardware and basic control systems. After Print Menu - changes how the printer reacts after the label has been printed.
Interfaces - changes interface parameters such as baud rate.
Menu Setting
Top Menu | Sub Menu | Default | Menu | Remarks |
|
|
|
|
|
*Page Setup | Print Speed | 4 IPS | 2 to 4 IPS | Printing speed setting |
|
|
|
|
|
| Print Darkness | 10 | 00 to 30 | Print darkness setting (printhead temperature) |
|
|
|
|
|
| Continuous Media | 4.00 IN | 0.25 to 32.00 IN | Setting default length of continuous |
| Length | 101.6mm | 6.35 to 812.8mm | media, if selected. |
|
|
|
|
|
| Vertical Position | 0.00 IN | Print start position adjustment; the | |
|
| 0.0mm | lower line is in metric mode. | |
|
|
|
|
|
| Horizontal Shift | 0.00 IN | Horizontal printing location adjustment | |
|
| 0.0mm | 25.4 to 25.4mm |
|
|
|
|
|
|
| Media Sensor | See Through | See Through | Label sensor selection |
|
|
| Reflect |
|
|
|
| None |
|
|
|
|
|
|
| Small Media | OFF | ON | Setting for small labels |
| Adjustment |
| OFF |
|
|
|
|
|
|
| Small Media | 1.00 IN | 0.25 to 1.00 IN | Setting length of small label media |
| Length | 25.4mm | 6.35 to 25.4mm |
|
|
|
|
|
|
*System Setup | Sensor Level | 1.5V | 0.0V to 3.3V | Setting the threshold of the sensor |
|
|
|
|
|
| Buzzer Select | ON | ON | Setting buzzer sounding conditions |
|
|
| OFF |
|
|
|
|
|
|
| Metric/Inch | Inch | Inch | Setting the units used |
|
|
| mm |
|
|
|
|
|
|
| Max Media Length | 10.00 IN | 1.00 to 50.00 IN | Setting the maximum label length |
|
| 254.0mm | 25.4 to 1270.0mm |
|
|
|
|
|
|
| Settings Lock | Off | On/Off | When on, prevents software commands from |
|
|
|
| changing the values set by the VuePrint menu |
|
|
|
|
|
| Keyboard Lock | Off | On/Off | Prevents the control panel from affecting the |
|
|
|
| printer's conrfiguration. (User |
|
|
|
|
|
| Control Code | STD | STD/ALT | Uses the command instead of STX in DMX |
| (DMX Mode Only) |
|
| mode. Sometimes called "AS400 emulation" |
|
|
|
|
|
| Emulation Select | DM4 |
| Datamax compatibility selection |
|
|
| DMI | DMI DataMax IClass |
|
|
| DM4 | DM4 DataMax 430 like |
|
|
| DPP | DPP DataMax Prodigy Plus |
|
|
|
|
|
32