Citizen CLP-9001, CLP-9301 Interfaces, Serial interface, Specifications, XON/XOFF protocol

Models: CLP-9301 CLP-9001

1 78
Download 78 pages 50.46 Kb
Page 69
Image 69

Chapter 9 Specifications

9.2 Interfaces

1 Serial interface

Specifications

Transfer method:

Start stop synchronous dual communication system

Signal level:

RS-232C

Baud rate:

2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps

Data bits:

7 or 8

Start bits:

1

Stop bits:

1 or 2

Parity:

Even, odd, or none

Connector:

D-SUB 25PIN 17LE-13250-27(D41)(DDK) or its equivalent

XON/XOFF protocol

XON code output requirements:

Communication is enabled after power is turned ON.

Residual capacity of the buffer is 1K bytes or more after sending XOFF code.

XOFF code is output due to error and printer returns to normal conditions.

XOFF code output requirements:

Printer is in error.

Printer is in paused state.

Receive buffer has less than 128 bytes available.

16KB

1K bytes

128 bytes

Receive Buffer

XON code output

XOFF code output

56

Page 69
Image 69
Citizen CLP-9001, CLP-9301 user manual Interfaces, Serial interface, Specifications, XON/XOFF protocol