Configuring the Scale
Scale Operating Menu (Overview)
Setting the Parameters (Menu Codes)
You can configure your CT scale to meet individual requirements by selecting from the parameters available in the menu.
Example: Adapt the scale to unstable ambient conditions: Menu code 1 .1 .4
Step | Key (or instruction) Display |
1. Turn off the scale | [ON/OFF] |
oFactory setting
⎟User setting
1
level Menu
Menu 1. Scale functions
2
level Menu
1.1.Adapt filter
1.3.Stability range
3 | setting | 4 |
level | level | |
Menu Factory | Menu |
|
1.1.1Minimum vibration
1.1.2o Normal vibration
1.1.3Strong vibration
1.1.4Extreme vibration
1.3.11/4 digit
1.3.21/2 digit
1.3.31 digit
1.3.4o 2 digits
1.3.54 digits
2 | . Turn the scale back on | [ON/OFF] |
|
|
| while all segments | t briefly | 1. |
|
| are displayed |
|
| |
$ | To navigate within a menu | t | 2. |
|
| level; the last menu | repeatedly | … |
|
| option is followed by the |
| 9. |
|
| first option |
| 1. |
|
3 | . Select the 2nd menu level | [PRINT] | 1. | 1. |
4 | . Select the 3rd menu level | [PRINT] | 1. | 1. 2 o |
5 | . In Menu Level 3: | t | 1. 1. 4 |
2. Application programs
3. Application
1.6.Auto zero
1.7.Weight unit 1
2.1.Program selection
3.1. Weight unit 2
3.3.Reference qty or %
1.6.1o O n
1.6.2Off
See “Toggle between Weight Units”
see the desired application program description
see “Toggle between Weight Units”
see the desired application program description
| Select the desired option | repeatedly |
| |
6. Confirm new setting; the |
|
| ||
| “o” | indicates the currently | [PRINT] for 2 sec. | 1. 1. 4 o |
| set | option | ||
$ | Select the next menu level |
|
| |
| (here: move from the 3rd to |
| 1. | |
| the 1st level) | [PRINT] | ||
$ | Set other menu codes, | [PRINT], t |
| |
| if desired |
|
| |
7. Store parameter settings | t |
| ||
| and exit operating menu | for 2 sec. |
| |
| or |
|
|
|
$ | Exit operating menu without | [ON/OFF] |
| |
| storing changes |
| ||
> | Restart the application |
| 0.000 ct |
5. through 7.
8. Extra functions
9. Reset menu
applies only if an interface is installed; see the corresponding instructions
8.1. Menu |
|
| 8.1.1 | o | Parameter | settings |
|
|
|
|
| alterable |
|
|
|
| 8.1.2 |
| Parameter | settings |
|
|
|
| |||
|
|
|
|
| read only |
|
8.2. External |
|
|
| applies only if an interface | |||
switch function | is installed; see the | ||||||
|
|
|
|
| corresponding | instructions | |
8.3. |
|
| 8.3.1 | Off/on | (battery | ||
mode |
|
| shuts off | ||||
|
|
|
|
|
| automatically after | |
|
|
|
|
|
| 3 min) |
|
|
|
|
|
| 8.3.2 o | ||
|
|
|
|
| |||
9.– Factory |
| 9.– 1 | Reset |
| |||
settings |
| 9.– 2 o | Do not reset | ||||
|
7