6.2 DIP Switch Functions

DIP Switches

Switch No.

Function

ON

 

OFF

Factory

 

Setting

 

 

 

 

 

1

Setting and selecting

DIP switch setting is

DIP switch setting is

ON

 

condition for communication

enabled.

disabled.

 

2

Communication mode

Xon/Xoff

 

DTR/DSR

OFF

3

Bit length

7-bit

 

8-bit

OFF

4

Parity check

With parity

 

No parity

OFF

5

Selecting parity

Even parity

 

Odd parity

OFF

6

 

 

 

 

ON

Selecting baud rate

(See Table 1)

7

ON

 

 

 

 

 

 

 

 

8

INIT

Reset

 

Disabled

OFF

Table 1

Selecting baud rate

 

 

 

 

 

Baud Rate

 

 

Switch No.

(bps)

 

6

7

2,400

 

 

OFF

OFF

4,800

 

 

ON

OFF

9,600

 

 

OFF

ON

19,200

 

 

ON

ON

— 46 —