![](/images/backgrounds/148716/148716-5650x1.png)
Appendix
Interfaces
Serial Interface7 SpecificationsTransmission method | Two way serial communication |
Signal level | |
Baud rate | 600/1,200/2,400/4,800/9,600/ |
| 19,200/38,400/57,600/11,500 bps |
Data length | 7 or 8 bit |
Start bit | 1 bit |
Stop bit | 1 bit, 2 bits |
Parity | Even, odd, none |
Connector |
No. | Name | I/O |
| Pin explanation |
1 | CTS | IN | XON/OFF: | not used |
|
|
| DTR/DSR: | not used |
2 | RTS | OUT | Pull up to + 10V through 3.3 kΩ | |
3 | RXD | IN | Data beam from the host to the printer | |
4 | SGND | – | GND of the signal line | |
5 | TXD | OUT | XON/OFF : Data beam from printer to host | |
|
|
|
| Transmits XON/XOFF |
|
|
| DTR/DSR : | Not used |
6 | DTR | OUT | XON/OFF : | Always High |
|
|
| DTR/DSR : | High when the printer can receive |
|
|
|
| Low when it cannot receive |
7 | IFSEL |
| Cable judgement when the optional RS232C cable is connected to | |
|
|
| the printer |
|
8 | DSR | IN | XON/OFF : Not used | |
|
|
| DTR/DSR : | High when the host can receive |
|
|
|
| Low when it cannot receive |
* IN: signal from host to printer, OUT: signal from the printer to host
50